Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 60
Filtrar
1.
Artículo en Inglés | MEDLINE | ID: mdl-38415804

RESUMEN

PURPOSE: Investigate survival and technical complications of two-unit posterior implant-supported cantilever made of monolithic zirconia on titanium-base abutments (Zr-TiB) vs. porcelain-fused-to-metal on castable gold abutments (PFM-GA) using two different implant connections, internal butt-joint (IBJ) and internal conical (IC). MATERIALS AND METHODS: Forty-eight implants (4.3 mm diameter) were divided into four groups (n = 12) to support 2-unit mandibular premolar cantilevers with two different materials (Zr-TiB vs. PFM-GA) and two connection types (IBJ vs. IC). Tested groups were as follows: (1) IBJ/Zr-TiB; (2) IBJ/PFM-GA; (3) IC/Zr-TiB; and (4) IC/PFM-GA. Specimens were thermomechanical aged (1,200,000 cycles, 98 N, 5-55°C) with occlusal axial load on the pontic. Catastrophic and non-catastrophic events were registered, and removal torque values measured before and after aging. Specimens surviving aging were subjected to loading until failure. Survival, total complication rates, torque loss (%), and bending moments were calculated. RESULTS: From 48 specimens, 38 survived aging. Survival rates significantly varied from 16.7% (IC/PFM-GA) to 100% (IBJ/Zr-TiB; IBJ/PFM-GA; IC/Zr-TiB) (p < .01). Internal conical connection revealed significantly higher torque loss (IC/ZrTiB - 67%) compared to internal butt-joint (IBJ/Zr-TiB - 44%; IBJ/PFM-GA - 46%) (p < .01). Bending moments were higher in internal butt-joint connections than in internal conical (p < .05). CONCLUSION AND CLINICAL IMPLICATIONS: Two-unit posterior implant-supported cantilever FDPs replacing mandibular premolars composed of monolithic zirconia on titanium-base abutments demonstrated higher mechanical stability compared to porcelain-fused-to-metal on castable gold abutments in this in vitro study. The internal conical connection combined with porcelain-fused-to-metal on gold abutments revealed a high number of failures; therefore, their clinical use may be considered cautiously for this indication.

2.
Clin Oral Implants Res ; 35(4): 377-385, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38170349

RESUMEN

OBJECTIVES: The aim of this study was to evaluate the effect of sterilization on the retention forces of lithium disilicate (LD) and polymer-infiltrated ceramic network (PICN) crowns bonded to titanium base (Ti-base) abutments. MATERIALS AND METHODS: Forty LD and 40 PICN crowns were milled and then bonded to 80 Ti-bases with two resin composite cements: Multilink Hybrid Abutment (mh) and Panavia V5 (pv) for a total of 8 groups (n = 10). Half of the specimens (test) underwent an autoclaving protocol (pressure 1.1 bar, 121°C, 20.5 min) and the other half not (control). Restorations were screw-retained to implants, and retention forces (N) were measured with a pull-off testing machine. The surfaces of the Ti-bases and the crowns were inspected for the analysis of the integrity of the marginal bonding interface and failure mode. Student's t-test, chi-square test, and univariate linear regression model were performed to analyze the data (α = 0.05). RESULTS: The mean pull-off retention forces ranged from 487.7 ± 73.4 N to 742.2 ± 150.3 N. Sterilized groups showed statistically significant overall higher maximum retention forces (p < .05), except for one combination (LD + mh). Sterilization led to an increased presence of marginal gaps and deformities compared to no-sterilization (p < .001), while no statistically significant relationship was found between failure mode and sterilization (p > .05). CONCLUSIONS: Sterilization may have a beneficial effect on the retention forces of LD and PICN crowns bonded to titanium base abutments, although it may negatively influence the integrity of the marginal bonding interface.


Asunto(s)
Polímeros , Titanio , Porcelana Dental , Coronas , Ensayo de Materiales , Circonio , Cerámica , Análisis del Estrés Dental , Pilares Dentales , Diseño Asistido por Computadora
3.
Artículo en Inglés | MEDLINE | ID: mdl-37929698

RESUMEN

AIM: This study aimed to investigate the influence of titanium base (ti-base) abutment macro- and micro-geometry on the mechanical stability of polymer-infiltrated ceramic network (PICN) screw-retained implant-supported single crowns (iSCs). MATERIALS AND METHODS: Twelve specimens per group were used, comprising six different implant/ti-base abutment combinations restored with PICN iSCs: Nb-T (gingival height [GH]: 1.5 mm, prosthetic height [PH]: 4.3 mm), CC (GH: 0.8 mm, PH: 4.3 mm), CC-P (GH: 0.8 mm, PH: 7 mm), Nb-V (GH: 1.5 mm, PH: 6 mm), St (GH: 1.5 mm, PH: 5.5 mm), and Th (GH: 0.5 mm, PH: 9 mm). The specimens underwent thermo-mechanical aging, and those that survived were subsequently subjected to static loading until failure. The data were analyzed using a one-way ANOVA test followed by Tukey post hoc test (α = .05). RESULTS: All specimens survived thermo-mechanical aging without complications, namely, visible cracks, debonding, or screw loosening. Th group demonstrated the highest strength values among all the groups, with significant differences compared to Nb-T (p < .05), CC (p < .001), and St (p < .001). Additionally, CC-P group exhibited significantly superior fracture strength results compared to CC (p < .05) and St (p < .05). CONCLUSION: The choice of ti-base, particularly prosthetic height, had a significant influence on fracture resistance of PICN iSCs. Nevertheless, the height or geometrical features of the ti-base did not exhibit a significant influence on the mechanical behavior of the iSC/ti-base assembly under thermomechanical loading, as all specimens withstood the aging without complication or failure.

4.
Int J Esthet Dent ; 18(4): 325-326, 2023 10 11.
Artículo en Inglés | MEDLINE | ID: mdl-37819560

Asunto(s)
Medicina , Humanos , Predicción
5.
Int J Prosthodont ; 0(0): 0, 2023 Sep 20.
Artículo en Inglés | MEDLINE | ID: mdl-37729480

RESUMEN

PURPOSE: To evaluate the accuracy of complete-arch digital implant impressions using different intraoral scan body (ISB) materials and intraoral scanners (IOSs). MATERIALS AND METHODS: The mandibular dental cast of an edentulous patient with six tissue-level dental implants was used as master cast. Two types of ISBs, polyether-ether-ketone (PEEK) and plasma-coated medical titanium, were used with five IOSs: TRIOS 4 (T4), Virtuo Vivo (VV), Medit i700 (Mi700), iTero5D (i5D), and Primescan (PS). To assess accuracy, digital impressions (n=10) with each IOS and ISB were compared to two reference models obtained by digitizing the master cast with each ISB type using a desktop scanner (IScan4D LS3i) and importing the scan data into metrology software (Geomagic Control X). Root-mean-square (RMS) error was employed to evaluate overall deviation values (trueness), while precision was determined using the standard deviation (SD) of RMS values. Statistical significance was set at P < 0.05. The Kruskal-Wallis test was used, followed by the pairwise comparison method with Bonferroni correction (α=.05). RESULTS: An interaction between ISB material and IOS was found (P=0.001). Plasma-coated medical titanium ISBs demonstrated significantly higher trueness and precision compared to PEEK ISBs with T4 (P=0.001), Mi700 (P=0.001; P=0.004), and i5D (P=0.001). Conversely, VV exhibited higher trueness and precision values with PEEK ISBs (P=0.005; P=0.003). PS provided the highest trueness and precision regardless of the ISB material (P=0.912). T4 showed the lowest accuracy for PEEK ISBs, and VV for plasma-coated medical titanium ISBs. CONCLUSION: Except for PS, all IOSs showed significant differences between ISB materials. PS demonstrated the highest accuracy with both ISB materials, whereas T4 had the lowest accuracy for PEEK ISBs, and VV showed the lowest accuracy for plasma-coated medical titanium ISBs.

6.
J Prosthet Dent ; 2023 Aug 01.
Artículo en Inglés | MEDLINE | ID: mdl-37537105

RESUMEN

STATEMENT OF PROBLEM: The absence of fixed reference points can affect the trueness of complete-arch intraoral digital implant scans. The effect of splinting intraoral scan bodies (ISBs) or the inclusion of artificial landmarks (AL) on the trueness of complete-arch digital implant scans is still unclear. PURPOSE: The purpose of this study was to analyze the effect of splinting ISBs or the inclusion of AL on the trueness of complete-arch digital implant scans with 5 intraoral scanners (IOSs). MATERIAL AND METHODS: Six tissue-level dental implants (Straumann Tissue Level) were placed in an edentulous patient, and the correspondent definitive cast was digitized with a desktop scanner (IScan4D LS3i) to obtain the reference digital cast. Digital scans (n=10) were performed with 5 IOSs: TRIOS 4, Virtuo Vivo, Medit i700, iTero Element 5D, and Cerec Primescan. Three different scanning techniques were evaluated: conventional (cIOSs), splinted (sIOSs), and AL (AL-IOSs). The scan data obtained were imported into a metrology software program and superimposed to the reference digital cast by using a best-fit algorithm. The overall deviations of the positions of the ISBs were evaluated by using the root-mean-square (RMS) error (α=.05). RESULTS: The mean ±standard deviation trueness values for the cIOSs, sIOSs, and AL-IOSs groups were 48 ±8 µm, 53 ±7 µm, and 49 ±11 µm, respectively, with no statistically significant differences (P=.06). Significant differences were found for the IOSs used with each technique (P<.001). Primescan (27 ±4 µm cIOSs; 28 ±3 µm sIOSs; 31 ±3 µm AL-IOSs) showed significantly higher trueness than iTero 5D (47 ±5 µm cIOSs; 47 ±4 µm sIOSs; 50 ±6 µm AL-IOSs) (P=.002) and TRIOS 4 (93 ±18 µm cIOSs; 76 ±18 µm sIOSs; 107 ±13 µm AL-IOSs) (P=.001) for all techniques. In addition, no significant differences were found between the techniques by using iTero 5D or Primescan (P=.348 and P=.059, respectively). CONCLUSIONS: The cIOSs, sIOSs, and AL-IOSs techniques showed similar trueness. The IOS used influenced the trueness of complete-arch digital implant scans.

7.
Int J Esthet Dent ; 18(1): 9-10, 2023 Feb 03.
Artículo en Inglés | MEDLINE | ID: mdl-36734420
8.
Int J Prosthodont ; 36(5): 651, 2023 Nov 01.
Artículo en Inglés | MEDLINE | ID: mdl-36288489

RESUMEN

PURPOSE: To assess the influence of the bonding system and restorative material on the marginal integrity and pull-off forces of monolithic all-ceramic crowns bonded to titanium base (ti-base) abutments. MATERIALS AND METHODS: A total of 108 ti-bases were sandblasted and divided into nine experimental groups (n = 12) according to the combination of crown material (polymer-infiltrated ceramic-network [PI], lithium-disilicate [LD], and zirconia [ZI]) and bonding system (Multilink Hybrid-Abutment [MH], Panavia V5 [PV], RelyX Ul5mate [RU]) with the respective primers. After bonding the crowns to the ti-base abutments, the restorations were screw-retained on implants and thermomechanically aged (1,200,000 cycles, 49 N, 1.67 Hz, 5 to 55°C). Marginal integrity and bonding failures were evaluated under a light microscope, and pull-off forces (N) were calculated. Chi-square tests for marginal integrity as well as one-way and two-way ANOVA statistical tests for pull-off forces were applied (a = .05). RESULTS: PI presented higher marginal integrity than LD (P = .023). Bonding system PV revealed higher marginal integrity than MH (P =.005) and RU (P =.029). Differences in pull-off forces were found between restorative material and resin cements (P < .001), with the highest values for ZI + RU (598 ± 192 N), PI + PV (545 ± 114 N), LD + MH (532 ± 116 N), and PI + RU (528 ± 81 N). Specimens with marginal integrity revealed higher pull-off forces than those with alteration (P = .006). Specimens presenting bonding failures (micromovements) showed lower pull-off forces than those without bonding failures (P < .001). CONCLUSIONS: The tested CAD/CAM materials show favorable bonding performances with different bonding systems, nevertheless for each restorative material a specific bonding system has to be recommended. Int J Prosthodont 2023;36:e88-e102.


Asunto(s)
Materiales Dentales , Titanio , Coronas , Cerámica , Cementos de Resina , Ensayo de Materiales , Circonio , Diseño Asistido por Computadora , Análisis del Estrés Dental , Pilares Dentales
9.
Clin Oral Implants Res ; 34(1): 56-65, 2023 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-36321877

RESUMEN

OBJECTIVES: To investigate survival rates, technical and biologic outcomes of buccally micro-veneered all-ceramic single implant crowns. MATERIAL AND METHODS: Sixty subjects randomly received immediately or early placed implants. Crowns out of lithium-disilicate (n = 30) and zirconia-ceramic (n = 30) were bonded to titanium-base-abutments. Restorations were inspected at baseline (BL) and during follow-up visits (6, 12 months). Technical and biologic parameters were recorded. Data were analysed descriptively. Differences between groups were tested with Student's t-test. Paired T-test was used when comparing data from the same implant or tooth over time. Linear model repeated measures were used to test differences between materials over time. Differences in counts were evaluated using Pearson Chi-square test. The level of significance was at p < .05. RESULTS: After a mean observation time of 13.2 ± 2.4 months, 54 restorations were re-examined. The implant survival rate was 98.3%, and the restoration survival rate was 100%. One early implant failure occurred. Two minor chippings occurred in lithium-disilicate restorations. No chippings or fractures occurred in any zirconia restorations at 1 year (0%). The technical complication rate was 3.7%, with 7.7% complications among the lithium-disilicate restorations and no differences between the two materials (p = .558). At 1-year follow-up, mean Bleeding on Probing (BOP) was higher at implants (0.27 ± 0.3) than adjacent teeth (0.17 ± 0.18) (p = .046) with no differences between materials (p = .36). Differences in pocket probing depth (PPD) between implants and adjacent teeth were significant (p < .01). Jemt Index improved significantly from BL to 1-y-follow-up (p < .001). CONCLUSIONS: Preliminary results were good, suggesting that the ceramic type does not impact technical and biologic parameters.


Asunto(s)
Productos Biológicos , Titanio , Humanos , Proyectos Piloto , Litio , Fracaso de la Restauración Dental , Porcelana Dental , Coronas , Circonio , Cerámica , Pilares Dentales
11.
Int J Esthet Dent ; 17(4): 373-374, 2022 Nov 25.
Artículo en Inglés | MEDLINE | ID: mdl-36426609
12.
J Dent ; 127: 104334, 2022 12.
Artículo en Inglés | MEDLINE | ID: mdl-36257512

RESUMEN

OBJECTIVES: This in vitro research aimed to quantitatively evaluate the enamel and dentin tissue removal and the residual adhesion surface area (RAS) after different margin designs and locations for indirect partial restorations (IPR). METHODS: A human molar was scanned using a Micro-CT and the STL file obtained was used to 3D-print 50 resin-tooth replicas. IPR standardized preparations were performed. The specimens were randomly assigned to 5 groups (n = 10), according to preparation and margin location to the dental equator (DE): 1) Rounded shoulder above the DE (SA); 2) Hollow chamfer above the DE (CA); 3) Butt joint above the DE (BJ); 4) Rounded shoulder below the DE (SB); 5) Chamfer below the DE (CB). Then, the tooth replicas were scanned and each STL file was aligned and superimposed to the original STL model file. Data of enamel and dentin volume removal and RAS were assessed and statistically analyzed (one-way ANOVA and Kruskal-Wallis tests for the two dental substrates respectively). Significance was set at p<0.05. RESULTS: Differences in dental tissue reductions were related to the margin location. Above the equator, SA, CA, and BJ performed comparably (p>0.05). Below the equator, CB was significantly more conservative in enamel reduction than SB (p<0.05) and showed the highest enamel adhesive surface exposure among the tested preparations (p<0.05). CONCLUSIONS: When the preparation margin is placed above DE, BJ determines a greater exposure of dentin, reducing the adhesive surface in enamel. Below DE, SB seems to be more aggressive in terms of tissue removal compared to CB. CLINICAL SIGNIFICANCE: The results of this in vitro study suggest that in teeth requiring partial restoration with the margin below the dental equator, a chamfer preparation would be more conservative than a shoulder preparation. When above the equator, preparations with flat designs would expose more dentine providing a worse substrate for adhesion.


Asunto(s)
Grabado Ácido Dental , Preparación de la Cavidad Dental , Humanos , Grabado Ácido Dental/métodos , Resinas Compuestas , Esmalte Dental/diagnóstico por imagen , Restauración Dental Permanente/métodos , Dentina/diagnóstico por imagen , Cementos de Resina , Microtomografía por Rayos X
13.
Artículo en Inglés | MEDLINE | ID: mdl-35472115

RESUMEN

Connective tissue grafts have become a standard for compensating horizontal volume loss in immediate implant placement. The use of new biomaterials like acellular matrices may avoid the need to harvest autogenous grafts, yielding less postoperative morbidity. This randomized comparative study evaluated the clinical outcomes following extraction and immediate implant placement in conjunction with anorganic bovine bone mineral (ABBM) and the use of a porcine acellular dermal matrix (ADM) vs an autogenous connective tissue graft (CTG) in the anterior maxilla. Twenty patients (11 men, 9 women) with a mean age of 48.9 years (range: 21 to 72 years) were included in the study and randomly assigned to either the test (ADM) or control (CTG) group. They underwent tooth extraction and immediate implant placement together with ABBM for socket grafting and either ADM or CTG for soft tissue augmentation. Twelve months after implant placement, the cases were evaluated clinically and volumetrically. All implants achieved osseointegration and were restored. The average horizontal change of the ridge dimension at 1 year postsurgery was -0.55 ± 0.32 mm for the ADM group and -0.60 ± 0.49 mm for the CTG group. Patients of the ADM group reported significantly less postoperative pain. Using xenografts for hard and soft tissue augmentation in conjunction with immediate implant placement showed no difference in the volume change in comparison to an autogenous soft tissue graft, and showed significantly less postoperative morbidity.


Asunto(s)
Dermis Acelular , Implantes Dentales , Carga Inmediata del Implante Dental , Animales , Bovinos , Tejido Conectivo/trasplante , Femenino , Humanos , Carga Inmediata del Implante Dental/métodos , Masculino , Maxilar/cirugía , Porcinos , Extracción Dental , Alveolo Dental/cirugía
14.
Int J Prosthodont ; 35(1): 7-16, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35230351

RESUMEN

In recent years, numerous new dental materials have been introduced as alternatives to metal-ceramics for restorations on teeth and implants. This position paper presents the current evidence and respective clinical recommendations of the European Association for Osseointegration (EAO), one of the scientific partners of the International Journal of Prosthodontics, on material selection for single crowns (SCs) and multiple-unit implant-supported fixed dental prostheses (FDPs). Metal-ceramic restorations can be utilized in most clinical indications and are preferred to ceramic restorations in incidences such as long clinical implant crowns; cantilever implant restorations where one implant is supporting two crowns; implant-supported FDPs with extension units extending more than 7 to 8 mm (premolar size); implant-supported FDPs with more than two pontics; and implant-supported FDPs with small connector diameters due to limited intraocclusal space. Veneered or monolithic zirconia-ceramic and veneered or monolithic reinforced glass-ceramic implant-supported SCs are indicated for most SC cases in both the anterior and posterior areas. Today, implant-supported zirconia-ceramic FDPs that are conventionally veneered cannot be considered the material of first priority due to the pronounced risk for fracture of the framework and catastrophic fracture of the veneering material. Monolithic zirconia FDPs are a promising alternative to veneered implant-supported zirconia-ceramic FDPs. The mechanical stability of the translucent and shaded zirconia differs significantly between the grades of translucency. This must always be considered when clinical indications are recommended. As this specific area of prosthodontics is evolving fast, numerous studies evaluating different material options in implant prosthodontics are currently performed worldwide, and future consensus meetings will refine the present recommendations. The EAO will therefore regularly publish updated position papers on relevant topics.


Asunto(s)
Implantes Dentales , Fracaso de la Restauración Dental , Cerámica , Coronas , Porcelana Dental , Diseño de Prótesis Dental , Prótesis Dental de Soporte Implantado , Dentadura Parcial Fija , Oseointegración , Circonio
15.
Int J Oral Maxillofac Implants ; 37(1): 19-29, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35235616

RESUMEN

PURPOSE: This in vitro study evaluated technical outcomes of monolithic zirconia implant-supported fixed dental prostheses (iFDPs) supported by different designs of titanium base abutments after aging and static load testing. MATERIALS AND METHODS: Sixty three-unit monolithic zirconia (yttrium oxide partially stabilized tetragonal zirconia polycrystals; Y-TZP)iFDPs were produced and divided into four groups: group A-conical titanium base abutments for the prosthesis; group B-cylindrical titanium base abutments for the crown; group C-conical titanium base abutment for the prosthesis and cylindrical titanium base abutment for the crown; group D-cylindrical titanium base abutments for the prosthesis. The samples were subjected to an aging protocol and to continuous static loading until failure and analyzed visually and with specific software. The technical outcomes comprised the occurrence of debonding, screw loosening, deformation and fracture, abutment deformation and fracture, implant deformation and fracture, zirconia chipping and fracture, and bending moments. The Pearson chi-squared test (χ2) and Fischer exact test were used to compare the outcomes. The Kolmogorov-Smirnov test was used to evaluate data distribution of the bending moments. Analysis of variance (ANOVA) was used for the analysis of parametric data distribution, and the Kruskal-Wallis test was used for nonparametric data distribution. RESULTS: After aging, a higher percentage of debonding (P = .042) and micromovement (P = .034) was recorded in group C (P = .042). The conical titanium base abutments had a higher debonding (P = .049) and a higher macromovement rate (P = .05). The static load test showed higher bending moments in group D (P = .001) and lower bending moments in group A (P = .001). Debonding was highest in group C (P = .001) and lowest in group A (P = .002). Complete loss of retention rate was highest in group C (P = .001). The conical titanium base abutment had the highest debonding rate (P = .001) and complete loss of retention (P = .001). The micromovement rate was the highest for cylindrical titanium base abutments for the crown (P = .001). The lowest screw loosening, zirconia chipping, and fracture rate (P = .001) and the highest screw deformation (P = .004) were recorded in group A. The screw deformation rate was lowest in the cylindrical titanium base abutments for the crown (P = .008). CONCLUSION: The mixed titanium base abutment design comprising one conical and one cylindrical abutment in Y-TZP iFDPs led to the highest debonding rate. The cylindrical titanium base abutment for the prosthesis provided a lower percentage of debonding and the highest load resistance.


Asunto(s)
Diseño de Implante Dental-Pilar , Titanio , Coronas , Pilares Dentales , Fracaso de la Restauración Dental , Análisis del Estrés Dental , Laboratorios , Ensayo de Materiales , Titanio/química , Circonio/química
16.
Int J Esthet Dent ; 17(1): 9-10, 2022 Feb 17.
Artículo en Inglés | MEDLINE | ID: mdl-35175003
18.
J Prosthodont ; 31(S1): 58-69, 2022 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-34792821

RESUMEN

PURPOSE: To investigate the accuracy of additive manufacturing (AM) by means of internal fit of fixed dental prostheses (FDPs) fabricated with two AM technologies using different resins and printing modes (validated vs nonvalidated) compared to milling and direct manual methods. MATERIAL AND METHODS: Sixty 3-unit interim FDPs replacing the first mandibular molar were divided into 6 groups (n = 10): manual (Protemp 4), milled (Telio-CAD), and AM groups were subdivided based on AM technology (direct light processing (Rapidshape P30 [RS]) and stereolithography (FormLabs 2 [FL])) and the polymer type (P-Pro-C&B [St] and SHERAprint-cb [Sh]) (RS-St, RS-Sh, FL-St, FL-Sh). Validated (RS-Sh and RS-St) or nonvalidated (FL-St and FL-Sh) modes were adopted for AM. The specimens were scanned to 3D align (GOM inspect) according to the triple scan method. The internal space between the FDPs and preparation surfaces in four sites (marginal, axial, occlusal, and total) was measured using equidistant surface points (GOM Inspect). Statistical analysis was done using Kruskal Wallis and Dunn post-hoc tests. (α = 0.05). RESULTS: One AM group (FL-Sh) and milling exhibited better adaptation compared to manual and RS-St at molar site (p < 0.05). FDPs with St resin (FL-St and RS-St) displayed bigger marginal space than milled, FL-Sh, and RS-Sh. The nonvalidated printing mode showed better mean space results (p < 0.05) with higher predictability and repeatability (p < 0.001). CONCLUSIONS: The AM interim FDPs tested provided valid alternatives to the milled ones in regard to their accuracy results. The printing mode, resin, and the AM technology used significantly influenced the manufacturing accuracy of interim FDPs, particularly at the marginal area. The nonvalidated printing mode with lower-cost 3D printers is a promising solution for clinical applications.


Asunto(s)
Diseño Asistido por Computadora , Dentadura Parcial Provisoria , Adaptación Marginal Dental , Diseño de Prótesis Dental/métodos , Ensayo de Materiales , Diente Molar , Impresión Tridimensional
19.
Clin Oral Implants Res ; 32(12): 1444-1454, 2021 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-34543478

RESUMEN

OBJECTIVES: The main objective of the study was to compare the accuracy of full-arch digital implant impressions for fixed dental prosthesis under in vitro and in vivo conditions. MATERIALS AND METHODS: Eight patients (five women and three men) with at least one edentulous arch and with 4-6 osseointegrated implants participated in this study. For each edentulous arch (n = 10), experimental screw-retained titanium bar with attached four scan bodies was fabricated. The bar containing four scan bodies was screw-retained intraorally on implants and scanned with Trios 3 intraoral scanner eight times (IOS group, in vivo). Then, the bar was attached to the master cast and scanned eight times again with the same intraoral scanner (MIOS group, in vitro). Finally, the bar with scan bodies was scanned 8 times with a laboratory scanner (reference). Precision and trueness were calculated for 3 distances and 3 angles between the scan bodies (1-2, 1-3, and 1-4) in IOS and MIOS groups. RESULTS: Precision and trueness for the largest distance (1-4) were found to be 44 ± 18 µm and 32 ± 19 µm for the IOS group and 31 ± 16 µm and 30 ± 14 µm for MIOS group, respectively. Precision and trueness for the angle between the most distant scan bodies (1-4) were 0.22 ± 0.14° and 0.18 ± 0.10° for the IOS group and 0.16 ± 0.11° and 0.07 ± 0.05° for MIOS group, respectively. CONCLUSIONS: Intraoral conditions moderately affected the precision and trueness of Trios 3 (3Shape) intraoral scanner. Results of in vitro accuracy studies cannot be directly transferred to the clinical field.


Asunto(s)
Implantes Dentales , Técnica de Impresión Dental , Diseño Asistido por Computadora , Humanos , Imagenología Tridimensional , Modelos Dentales
20.
Materials (Basel) ; 14(12)2021 Jun 18.
Artículo en Inglés | MEDLINE | ID: mdl-34207110

RESUMEN

The aim of this study was to investigate the effects of saliva contamination and the cleaning of the bond surface of titanium base (ti-base) abutments on the bonding stability and retention force values. The bond surface of the ti-base abutments was treated with airborne-particle abrasion. After contamination, the ti-base abutments underwent different cleaning protocols: water spray (H2O); alcohol (ALC); suspension of zirconium particles (SZP); reapplied airborne-particle abrasion (APA); and a control condition without contamination and cleaning (CTR). All lithium disilicate crowns were bonded to the ti-base abutments using a primer and a self-curing composite. Bonded specimens underwent thermo-mechanical aging. Bond failure analysis and pull-off testing were performed. Bond failure occurred more frequently in groups H2O, ALC, SZP, and APA (p < 0.05). Significant differences in retention force values were only found between CTR and ALC (p < 0.05). Specimens which did not show bond failure after ageing had higher retention force values than the specimens that showed bond failure (p < 0.05). Saliva contamination with cleaning can degrade the bonding properties to titanium. For the retention force values, only the protocol with alcohol after contamination could not restore the values.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...